SYNTHITE EB-41 black insulating varnish

  • Favorite
Dongguan Huahan insulating materials Co. Ltd.

Business Type:Retailer

Country/Region:China

Ddu Verified

HOT Rank

8/10

Product Information

  • Pharmacopeia:CP
  • Package Type:5 GAL
  • Shelf Life:18 months
  • Storage:Below 25℃
  • Place of Origin:USA

Description

SYNTHITE EB-41 black insulating varnish

Product description

It is a high temperature resistant, fast curing, air drying, polyurethane varnish, and it is a good insulating paint.

All electrical and electronic parts of the coating.

Characteristic:

Fast drying, high temperature resistance, good chemical resistance

Good shielding for reconstruction and manufacture. Oil and moisture resistance, excellent abrasion resistance, excellent adhesion.

Typical applications:

Magnetic field coils, control coils, switch bases, moulded plastics, electrical connectors, and fuse pipes.

Electromagnetic coil, controller axis, printed circuit board, commutator end, porcelain, solder joint and stator coil end.

Typical performance

Physics

Color / appearance black

Density @ 77 F (25oC), 8.5 – 9 lb / gallon

Viscosity @ 77oF (25oC) brucellus viscometer CPS 200 - 400

Flash point 81of (27oC shape)

Treatment time "77oF (25oC) band, minimum non stickiness

Setting touch

Film thickness, milliliter / side, ASTM d-115 1.5 - 2.5

Diluent (solvent) t-200x

VOC content, ASTM D 6053, pound / gallon

Organic aerosol (calculation) 47%

JCD / DS / eb41.09/03

Electrical dielectric strength, ASTM D 115 volt / millimeter 1800V dry

1200V wet

Chemical resistance

Acid resistant (10% sulfuric acid) excellent

Alkali resistant (1% sodium hydroxide) excellent

Salt tolerance

Oil, d-115 through ASTM

Influence on Corrosion of copper

Application Guide

Mixing the mixed pigment because of some precipitation.  Impregnation, impregnation or

Spray。 As a requirement to provide many applications or thinning, and diluent for T-200.

Spray application, usually 25% - 20 thin.

The thickness of the film should be kept at no more than 2 milliliters per side for each application. This allows for completion

The release of the solvent and the proper treatment. The air is dry and can be processed in 30 minutes.

It can make the air dry for at least 24 hours for the best chemical resistance and abrasion resistance.

Special attention

Spray is the way to keep the spraying area clean. Filters and others

The waste in this area should be soaked in water and placed in a safe container.


You Might Also Like
Change a group
Inquiry Cart(0)